Products
PQube can Monitor either a Three Phase or a Single AC Voltage
and record power quality events including:
- Voltage Unbalance - Under Frequency event
- Voltage Sags/Dips - Over Frequency event
- Voltage Swells - THD (Voltage)
- Voltage Interruptions - TDD (Current)
- RMS Flicker (Pinst, Pst and Plt)
- 1-microsecond high-frequency impulse detection
- Detailed event recording, plus daily, weekly, monthly trends.
Cumulative probability, histograms and more.
CT4 is a plug-in module with four built-in Current Transformers. Just pass the conductors through 8.6mm Dia openings in the CTs.
Measures, calculates and records:
- Current Wavforms, infrush current and power flow
(kW, kWh, kVA, kVAh, kVAR, kVARh,tPF)
- Peak meters (Peak Amps, Peak kVA and Peak Watts,
Single Cycle, 1-second and 1-minute peaks. Useful for
sizing circuit breakers, UPS and transformers.
- Carbon footprint - enter your local electric power source
information to get CO2 footprint directly in Kilograms.
XCT4 is a plug-in module for use with external Current Transformers. Suitable for four channels of current monitoring.
If you already have CTs installed on site, use XCT4 instead of CT4 for for energy monitoring. Wire connection Minimum 20 AWG (0.52mm square) and Maximum 14 AWG (2.1 mm squre)
Products
Globex PQ
PQube can be powered either from external AC 24V or DC 24 to 48V. Or from the additional (optional) Module PS1. Module PS1 is suitable for AC 100 to 240VAC 50/60 Hz. Module PS1 is recommended for redundant power from different souces.
Ethernet Module includes:
- Web-server. When you type its assigned IP address in your
web browser. you can see a web site that contains all the
information that your PQube haas recorded. As well as the real
time meters and status information. Your remote PQube looks
like a disk on your computer.
- FTP (File Transfer Protocol) server. You can access all the files
on PQube from your computer. You can also send
Eevery PQube accepts two electrically-isolated probes. Use Module TH1 to monitor local ambient Temperature and Humidity. Mount another Module TH1 on a standard 2.5mm stereo extension cable for monitoring remote conditions like outside Temperature and Humidity.
Note: 2 meter long extension cable Part No. THC-2M is available
AC/DC voltage attenuator Module ATT1 can be connected to PQube's analog channels. Suitable for monitoring DC voltage in Data Centers. Can also be used to monitor high voltage AC. Comes with 5 meter cable to permit location of Module ATT1 in High Voltage area.